{"id":13744828,"url":"https://github.com/GliaX/Stethoscope","last_synced_at":"2025-05-09T04:31:04.872Z","repository":{"id":11982559,"uuid":"14557445","full_name":"GliaX/Stethoscope","owner":"GliaX","description":"A research-validated stethoscope whose plans are available Freely and openly. The cost of the entire stethoscope is between $2.5 to $5 to produce","archived":false,"fork":false,"pushed_at":"2023-11-09T16:23:08.000Z","size":60082,"stargazers_count":734,"open_issues_count":18,"forks_count":100,"subscribers_count":93,"default_branch":"master","last_synced_at":"2024-08-04T05:05:02.140Z","etag":null,"topics":["free-software","glia","medicine","open-hardware","open-source","stethoscope"],"latest_commit_sha":null,"homepage":"","language":"Ruby","has_issues":true,"has_wiki":null,"has_pages":null,"mirror_url":null,"source_name":null,"license":"other","status":null,"scm":"git","pull_requests_enabled":true,"icon_url":"https://github.com/GliaX.png","metadata":{"files":{"readme":"README.md","changelog":null,"contributing":null,"funding":null,"license":"LICENSE","code_of_conduct":null,"threat_model":null,"audit":null,"citation":null,"codeowners":null,"security":null,"support":null}},"created_at":"2013-11-20T13:36:54.000Z","updated_at":"2024-07-25T15:08:43.000Z","dependencies_parsed_at":"2022-07-15T18:00:31.215Z","dependency_job_id":null,"html_url":"https://github.com/GliaX/Stethoscope","commit_stats":null,"previous_names":[],"tags_count":0,"template":false,"template_full_name":null,"repository_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repositories/GliaX%2FStethoscope","tags_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repositories/GliaX%2FStethoscope/tags","releases_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repositories/GliaX%2FStethoscope/releases","manifests_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repositories/GliaX%2FStethoscope/manifests","owner_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/owners/GliaX","download_url":"https://codeload.github.com/GliaX/Stethoscope/tar.gz/refs/heads/master","host":{"name":"GitHub","url":"https://github.com","kind":"github","repositories_count":224811246,"owners_count":17373933,"icon_url":"https://github.com/github.png","version":null,"created_at":"2022-05-30T11:31:42.601Z","updated_at":"2022-07-04T15:15:14.044Z","host_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub","repositories_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repositories","repository_names_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/repository_names","owners_url":"https://repos.ecosyste.ms/api/v1/hosts/GitHub/owners"}},"keywords":["free-software","glia","medicine","open-hardware","open-source","stethoscope"],"created_at":"2024-08-03T05:01:16.840Z","updated_at":"2025-05-09T04:31:04.867Z","avatar_url":"https://github.com/GliaX.png","language":"Ruby","funding_links":[],"categories":["Ruby"],"sub_categories":[],"readme":"Stethoscope\n===========\n\nThis project aims to create a research-validated stethoscope whose plans are \navailable freely and openly. The goal is for the bell to cost ~USD$1-2 to produce, \nand the rest of the stethoscope to cost approximately the same. You can see the peer-reviewed publication relating to this stethoscope's validation here:\n\nhttp://journals.plos.org/plosone/article?id=10.1371/journal.pone.0193087\n\nCurrently, the stethoscope resulting from this project functions as well as the \nmarket gold standard, the Littmann Cardiology III.\n\n\nBill of Materials\n=================\n\n**Printed parts:**\n* 1 stethoscope head (head.stl)\n* 2 ear tubes (eartube.stl)\n* 1 Y-piece (y_piece.stl)\n* 1 Spring (spring.stl)\n* 1 Ring (ring.stl)\n\n**Other hardware:**\nSome vendors are suggested.\n* 40cm - 50cm Silicone 13mm (preferred) or 12mm OD, 8mm ID, 50 durometer\n  * [8MM I.D X 13MM O.D NGP60 Clear Translucent Silicone Hose Pipe Tubing](https://www.advancedfluidsolutions.co.uk/8mm-id-x-13mm-od-clear-transulcent-silicone-hose-pipe-tubing-2482-p.asp) (USD$7.34/meter)\n\n* 20cm Silicone 8mm (preferred) or 6mm OD, 4mm ID (cut into 10cm pieces), 60 durometer\n  * [4mm ID x 8mm OD](https://www.advancedfluidsolutions.co.uk/4mm-id-x-8mm-od-clear-transulcent-silicone-hose-pipe-tubing-2454-p.asp)\n\n* Diaphragm: 40mm diameter cut from a report cover with approx 0.35mm plastic sheet\n  * [In Business Report Covers](https://www.amazon.com/dp/B0CJCBC86X?_encoding=UTF8\u0026psc=1\u0026ref_=cm_sw_r_ud_dp_CY0Q8HRSQEBTA39H9VF2)(USD$8.99)\n  * You can cut the diaphragm by hand or with a stamp like [this one](https://www.amazon.ca/Karujimu-ki-jumbo-craft-circle-CN45004/dp/B001CBY41W)\n\n* Earbuds / Eartips: Any large-sized standard earbuds will do.\n  * [Silicone Earbuds 7 Pairs - Large size](https://www.amazon.ca/gp/product/B006VELFJY)\n \n**Optional hardware**:\n* Metal spring for holding ear tubes together\n\n\nPrint Instructions\n==================\n**INFILL MUST BE 100%** **INFILL MUST BE 100%** **INFILL MUST BE 100%** **INFILL MUST BE 100%**\n\n* Use PETG or ABS\n* Layer height: 0.2mm\n* Use PrusaSlicer 2.0 or above to import 3MF file\n* Modify filament and printer settings as needed.\n* **DO NOT MODIFY PRINT SETTINGS**\n* Export and print\n\n\nTroubleshooting\n===============\n\n* If the spring and eartubes do not fit well, go ahead and scale the spring as needed\n* If the head and ring do not fit well, use caution as you may be modifying the acoustics. You can scale the head a little.\n\n\nNotes\n=====\n\n* We do not use PLA due to deformation in heat and poor plastic quality in the spring causing early failure. PLA may be used, but the lifetime of the stethoscope will decrease significantly.\n\n* We do not use brims, but you may print the eartubes and Y-pieces with a brim of 2mm to ensure that none of the parts lift off.\n\n**INFILL MUST BE 100%** **INFILL MUST BE 100%** **INFILL MUST BE 100%.** Otherwise, the stethoscope will not produce a correct sound.\n\n\nAssembly Instructions\n=====================\n\nSee [this instructional video](https://www.youtube.com/watch?v=u-KNTc0POLA) for assembly instructions.\n\n* Attach the diaphragm (40mm) to the stethoscope head.\n* Attach the stethoscope head to the silicone tube.\n* Attach the silicone tube to the Y-Piece.\n* Attach spring to ear tubes.\n* Attach the Y-piece to the ear tubes.\n* Attach the ear tubes to the eartips / earbuds.\n* Test the stethoscope as per the validation instructions.\n\n\nPrinting the inserts\n====================\nThe inserts are included in the `manual` directory. Using 8.5 x 11 (Legal) paper,\nthey can be printed at 8.25\" page width with 95% scale for the top print and \n90% scale for the bottom print using GIMP.\n\nThe top insert is cut at 14.5cm and again at 1cm creating two labels of 13.5cm height.\nThese inserts are printed on adhesive material.\n\nThe bottom insert is cut at a width of 20cm with a height cuts at 25cm, 15cm, \n13.5cm and 3.5cm creating 10cm x 20cm inserts.\n\n\nChanging and creating SCAD files\n================================\n\n[CrystalSCAD](https://github.com/Joaz/CrystalScad) and [OpenSCAD](http://www.openscad.org/) \nwere used to create all STL files. To recreate the stethoscope head, simply do:\n\n``` shell\ngem install crystalscad\nruby source_files/stethoscope_head/stethoscope_head.rb\n```\n\nThe SCAD files output from CrystalSCAD are found in `source_files/stethoscope_head/output` and are named as follows:\n* PrintableStethoscopeHead1Assembly_output.scad - The head\n\n\nMass Manufacturing\n==================\nWe generally print 4 stethoscopes per plate to ensure that each stethoscope is created out of the same material.\n\nOur serial numbering system consists of two parts. The last number part is the total number of unique stethoscopes created since day 1. All numbers before that dash are spool identifiers involved in that stethoscope. For example:\n\n001-010 would be the tenth stethoscope made with the first spool in our inventory. If the first spool makes a total of 15 stethoscopes, then the first stethoscope of the second spool would be 002-016. If the twentieth stethoscope uses plastic from spool 002 and spool 003, it would be 002-003-020.\n\n\nOther stethoscopes\n==================\nOthers have made 3D printed stethoscopes too. See:\n* https://www.youmagine.com/designs/stethoscope-chestpiece\n\n\nLicensing notes\n===============\nAs per our understanding, hardware is not covered by copyright. However, we present\nour work under the TAPR OHL license insofar as it applies.\n","project_url":"https://awesome.ecosyste.ms/api/v1/projects/github.com%2FGliaX%2FStethoscope","html_url":"https://awesome.ecosyste.ms/projects/github.com%2FGliaX%2FStethoscope","lists_url":"https://awesome.ecosyste.ms/api/v1/projects/github.com%2FGliaX%2FStethoscope/lists"}