Fault-tolerant, fail-fast implementation of Modbus protocol in Go.
https://github.com/grid-x/modbus
golang modbus
Last synced: 6 months ago
JSON representation
Fault-tolerant, fail-fast implementation of Modbus protocol in Go.
- Host: GitHub
- URL: https://github.com/grid-x/modbus
- Owner: grid-x
- License: bsd-3-clause
- Created: 2018-02-27T15:44:49.000Z (over 8 years ago)
- Default Branch: master
- Last Pushed: 2025-11-20T12:52:04.000Z (8 months ago)
- Last Synced: 2025-11-20T13:17:07.686Z (8 months ago)
- Topics: golang, modbus
- Language: Go
- Homepage:
- Size: 498 KB
- Stars: 123
- Watchers: 21
- Forks: 38
- Open Issues: 12
-
Metadata Files:
- Readme: README.md
- License: LICENSE
Awesome Lists containing this project
- awesome-smartgrid - GoModbus - tolerant, fail-fast implementation of Modbus protocol in Go. (Industrial protocols / Modbus (Yes it's still alive))
README
# go modbus
Fault-tolerant, fail-fast implementation of Modbus protocol in Go.
# Supported functions
Bit access:
- Read Discrete Inputs
- Read Coils
- Write Single Coil
- Write Multiple Coils
16-bit access:
- Read Input Registers
- Read Holding Registers
- Write Single Register
- Write Multiple Registers
- Read/Write Multiple Registers
- Mask Write Register
- Read FIFO Queue
Device identification:
- Read Device Identification (Function Code 0x2B)
# Supported formats
- TCP
- Serial (RTU, ASCII)
- UDP
# Usage
Basic usage:
```go
// Modbus TCP
client := modbus.TCPClient("localhost:502")
// Read input register 9
results, err := client.ReadInputRegisters(context.Background(), 8, 1)
// Modbus RTU/ASCII
// Default configuration is 19200, 8, 1, even
client = modbus.RTUClient("/dev/ttyS0")
results, err = client.ReadCoils(context.Background(), 2, 1)
```
Advanced usage:
```go
// Modbus TCP
handler := modbus.NewTCPClientHandler("localhost:502")
handler.Timeout = 10 * time.Second
handler.SlaveID = 0xFF
handler.Logger = log.New(os.Stdout, "test: ", log.LstdFlags)
ctx := context.Background()
// Connect manually so that multiple requests are handled in one connection session
err := handler.Connect(ctx)
defer handler.Close()
client := modbus.NewClient(handler)
results, err := client.ReadDiscreteInputs(ctx, 15, 2)
results, err = client.WriteMultipleRegisters(ctx, 1, 2, []byte{0, 3, 0, 4})
results, err = client.WriteMultipleCoils(ctx, 5, 10, []byte{4, 3})
// Read device identification
// Supported codes: ReadDeviceIDCodeBasic, ReadDeviceIDCodeRegular, ReadDeviceIDCodeExtended
deviceInfo, err := client.ReadDeviceIdentification(ctx, modbus.ReadDeviceIDCodeBasic)
// Or for reading a specific object: ReadDeviceIDCodeSpecific
deviceInfo, err := client.ReadDeviceIdentificationSpecificObject(ctx, 0)
```
```go
// Modbus RTU/ASCII
handler := modbus.NewRTUClientHandler("/dev/ttyUSB0")
handler.BaudRate = 115200
handler.DataBits = 8
handler.Parity = "N"
handler.StopBits = 1
handler.SlaveID = 1
handler.Timeout = 5 * time.Second
ctx := context.Background()
err := handler.Connect(ctx)
defer handler.Close()
client := modbus.NewClient(handler)
results, err := client.ReadDiscreteInputs(ctx, 15, 2)
// Read device identification
// Supported codes: ReadDeviceIDCodeBasic, ReadDeviceIDCodeRegular, ReadDeviceIDCodeExtended
deviceInfo, err := client.ReadDeviceIdentification(ctx, modbus.ReadDeviceIDCodeBasic)
// Or for reading a specific object: ReadDeviceIDCodeSpecific
deviceInfo, err := client.ReadDeviceIdentificationSpecificObject(ctx, 0)
```
# Modbus-CLI
We offer a CLI tool to read/write registers.
## Usage
For simplicity, the following examples are all using Modbus TCP.
For Modbus RTU, replace the address field and use the `rtu-` arguments in order to use different baudrates, databits, etc.
```sh
./modbus-cli -address=rtu:///dev/ttyUSB0 -rtu-baudrate=57600 -rtu-stopbits=2 -rtu-parity=N -rtu-databits=8 ...
```
For Modbus UDP, replace the address field with a UDP address.
```sh
./modbus-cli --address=udp://127.0.0.1:502 ...
```
### Reading Registers
Read 1 register and get raw result
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=1 -type-parse=raw -register=42
```
Read 1 register and decode result as uint16
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=1 -type-parse=uint16 -register=42
```
Read 1 register and get all possible decoded results
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=1 -type-parse=all -register=42
```
Read 2 registers and decode result as uint32
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=2 -type-parse=uint32 -register=42
```
Read 2 registers and get all possible decoded results
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=2 -type-parse=all -register=42
```
Reading multiple registers is only possible in the raw format
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -quantity=16 -type-parse=raw -register=42
```
### Writing Registers
Write 1 register
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -fn-code=0x06 -type-exec=uint16 -register=42 -write-value=7
```
Write 2 registers
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -fn-code=0x10 -type-exec=uint32 -register=42 -write-value=7
```
### Reading Device Identification
Read basic device identification information using function code 43 (0x2B) and code 1 (ReadDeviceIDCodeBasic):
```sh
./modbus-cli -address=tcp://127.0.0.1:502 -fn-code=43 -device-id-code=1
```
## Release
To release the Modbus-CLI tool, run either `make release` if you have installed `goreleaser` or `make ci_release`.
The generated files can be found in the directory in the `dist` directory.
Take the `.tar.gz` and `.zip` files and create a new GitHub release.
# References