https://github.com/jalle19/eda-modbus-bridge
An HTTP/MQTT bridge for Enervent EDA ventilation units
https://github.com/jalle19/eda-modbus-bridge
eda enervent homeassistant homeassistant-addons modbus mqtt rs485
Last synced: about 2 months ago
JSON representation
An HTTP/MQTT bridge for Enervent EDA ventilation units
- Host: GitHub
- URL: https://github.com/jalle19/eda-modbus-bridge
- Owner: Jalle19
- License: gpl-3.0
- Created: 2020-10-10T18:27:30.000Z (over 4 years ago)
- Default Branch: master
- Last Pushed: 2025-03-09T18:22:32.000Z (about 2 months ago)
- Last Synced: 2025-03-17T22:38:10.364Z (about 2 months ago)
- Topics: eda, enervent, homeassistant, homeassistant-addons, modbus, mqtt, rs485
- Language: TypeScript
- Homepage:
- Size: 1.59 MB
- Stars: 17
- Watchers: 3
- Forks: 3
- Open Issues: 1
-
Metadata Files:
- Readme: README.md
- Changelog: CHANGELOG.md
- License: LICENSE
Awesome Lists containing this project
README
# eda-modbus-bridge
[](https://github.com/Jalle19/eda-modbus-bridge/actions/workflows/codeql-analysis.yml)
[](https://github.com/Jalle19/eda-modbus-bridge/actions/workflows/test.yml)An HTTP/MQTT bridge for Enervent ventilation units with EDA or MD automation (e.g. Pingvin, Pelican and Pandion). It
provides a REST-ful HTTP interface for interacting with the ventilation unit (reading temperatures and changing certain
settings), as well as an MQTT client which can publish readings/settings regularly and be used to control the
ventilation unit.Communication happens over RS-485 (Modbus RTU) by connecting a serial device to the "Freeway" port on the ventilation
unit's computer board, or alternatively using Modbus TCP for newer units that can be connected to the local network.## Table of contents
* [Features](#features)
* [Requirements](#requirements)
* [Installation](#installation)
* [Running as a systemd service](#running-as-a-systemd-service)
* [Running as a Home Assistant OS addon](#running-as-a-home-assistant-os-addon)
* [Usage](#usage)
* [HTTP endpoints](#http-endpoints)
* [MQTT support](#mqtt-support)
* [Home Assistant MQTT discovery](#home-assistant-mqtt-discovery)
* [Known issues](#known-issues)
* [Troubleshooting](#troubleshooting)
* [License](#license)
* [Credits](#credits)## Features
* HTTP API for reading temperatures, modes, alarms and settings, as well as changing some settings
* Full MQTT support, including Home Assistant MQTT discovery support## Requirements
* Node.js 18.x or newer
* An Enervent ventilation unit with EDA or MD automation (Pingvin, Pandion, Pelican and LTR-3 confirmed working)
* An RS-485 device (e.g. `/dev/ttyUSB0`) connected to the Enervent unit's Freeway port (see
[docs/CONNECTION.md](./docs/CONNECTION.md) for details on how to connect to the unit). Newer units that can be
connected directly to the local network don't need this.## Installation
The following instructions will install the application to `/opt/eda-modbus-bridge`.
```bash
sudo su -
git clone https://github.com/Jalle19/eda-modbus-bridge.git /opt/eda-modbus-bridge
cd /opt/eda-modbus-bridge
npm install
npm run build
```That's it, the application is now installed. You can run it manually with
`node /opt/eda-modbus-bridge/dist/eda-modbus-bridge.js`, or see the next chapter on how to run it as a system service.### Running as a systemd service
The following instructions assume you've installed the application to `/opt/eda-modbus-bridge`.
```bash
sudo cp /opt/eda-modbus-bridge/systemd/eda-modbus-bridge.service /etc/systemd/system/
sudo systemctl enable eda-modbus-bridge
sudo systemctl start eda-modbus-bridge
```You can now check that it is running with `sudo systemctl status eda-modbus-bridge`.
If you need to change any command-line options (e.g. to configure the MQTT broker URL),
edit `/etc/systemd/system/eda-modbus-bridge`. After you have edited the file you need to reload systemd and restart
the application:```bash
sudo systemctl daemon-reload
sudo systemctl restart eda-modbus-bridge
```### Running as a Home Assistant OS addon
See https://github.com/Jalle19/home-assistant-addon-repository/tree/main/eda-modbus-bridge
## Usage
```
node dist/eda-modbus-bridge.js [options]Options:
--help Show help [boolean]
--version Show version number [boolean]
-d, --device The serial device to use, e.g. /dev/ttyUSB0
[required]
-s, --modbusSlave The Modbus slave address [default: 1]
--http Whether to enable the HTTP server or not
[boolean] [default: true]
-a, --httpListenAddress The address to listen (HTTP) [default: "0.0.0.0"]
-p, --httpPort The port to listen on (HTTP) [default: 8080]
-m, --mqttBrokerUrl The URL to the MQTT broker, e.g. mqtt://localhost:18
83. Omit to disable MQTT support.
--mqttUsername The username to use when connecting to the MQTT bro
ker. Omit to disable authentication.
--mqttPassword The password to use when connecting to the MQTT bro
ker. Required when mqttUsername is defined. Omit to
disable authentication.
-i, --mqttPublishInterval How often messages should be published over MQTT (i
n seconds) [default: 10]
--mqttDiscovery Whether to enable Home Assistant MQTT discovery sup
port. Only effective when mqttBrokerUrl is defined.
[boolean] [default: true]
-v, --debug Enable debug logging [boolean] [default: false]
```## HTTP endpoints
There's a Postman collection under `docs/`. For more information about the individual endpoints, see
[docs/HTTP.md](./docs/HTTP.md).## MQTT support
When an MQTT broker URL is specified, the application connects to the broker and starts to regularly publish data at
the configured interval (defaults to every 10 seconds). Device information is published only on startup and retained
in the broker.Every topic is prefixed by `eda/`, so to subscribe to everything the application sends out, subscribe to `eda/#`
See [docs/MQTT.md](./docs/MQTT.md) for more detailed information about which topics are published and subscribed to.
### Home Assistant MQTT discovery
The application supports Home Assistant's MQTT Discovery feature, meaning your ventilation unit will show up as a device
in Home Assistant automatically through the MQTT integration. The following entities are available:* sensors for all readings
* numbers (configurable) for settings
* switches for the ventilation modes and settings
* binary sensors for the alarms
* a button for acknowledging the latest alarm


## Known issues
* Some ventilation units sometimes trip the "TE20 Huoneilma kuuma" alarm when Modbus is used and a room temperature
sensor has not been connected to the main board. This can be alleviated by reducing the polling interval from 10
seconds to something like 30 seconds, or fixed permanently by either connecting an NTC10 temperature sensor or a 10
kilo-ohm resistor to the sensor input terminals (not tested, but confirmed by Enervent).* It is not possible to adjust the ventilation level when the unit is operating in normal mode. Enervent has confirmed
that this is a limitation in the protocol and there is no direct solution. A workaround is to repurpose one of the
modes, e.g. "long away", to be a "manual control" mode, since the ventilation level can be adjusted for all non-
normal modes of operation. A slight caveat with this is that the temperature target is also reduced, and the
temperature target reduction setting doesn't always seem to accept values below 2 degrees Celsius. Experiment with
these values to find something that suits your use case, or trust the built-in automation in the ventilation unit to
do its job.* Older firmware (e.g. Pingvin devices with software version 2.01) only support a smaller list of Modbus registers, so
some functionality may be missing. Open an issue if you feel like something isn't working that should be working.
Unsupported functionality is indicated by the corresponding sensor being disabled in Home Assistant, and the readings
missing from the `/summary` HTTP endpoint. However, some functionality cannot be reliably detected as available or
not available, so try enabling any disabled sensors you're interested in to see if they actually report some values.
This seems to be especially common on Pandion units (or any unit that use firmware version 5.x).* While it's possible to acknowledge any active alarm, serious alarms that cause the unit to enter the "emergency stop"
state require a restart of the unit to resume normal operation. However, the unit cannot be restarted via Modbus
(at least not officially), so it's best to acknowledge such alarms manually.* Some readings may be nonsensical depending on the exact ventilation unit used, e.g. "Exhaust air temperature
(before heat recovery)" can erroneously show -40 °C.## Troubleshooting
See [docs/CONNECTION.md](./docs/CONNECTION.md)
## License
GNU GENERAL PUBLIC LICENSE 3.0
Some documentation under `docs/` is proprietary.
## Credits
Credits to Jaakko Ala-Paavola for creating https://web.archive.org/web/20201020102005/http://ala-paavola.fi/jaakko/doku.php?id=pingvin
and self-hosting a copy of the relatively hard to find EDA modbus register PDF document.