https://github.com/jnewland/mpr-6zhmaut-api

JSON API wrapper for the RS-232 interface of the Monoprice 6 Zone Home Audio Multizone Controller and Amplifier Kit (MPR-6ZHMAUT)
https://github.com/jnewland/mpr-6zhmaut-api

home-automation

Last synced: about 16 hours ago
JSON representation

JSON API wrapper for the RS-232 interface of the Monoprice 6 Zone Home Audio Multizone Controller and Amplifier Kit (MPR-6ZHMAUT)

Awesome Lists containing this project

README

        

# mpr-6zhmaut-api

> :warning: I no longer use this software, instead using [`remserial`](https://github.com/jnewland/remserial) and the [official Home Assistant integration](https://www.home-assistant.io/integrations/monoprice/) for the same device.

Monoprice sells this wacky [6 zone amp](https://www.monoprice.com/product?p_id=10761) with a serial interface. This tiny project wraps the serial interface with a JSON API.

[A detailed walk-through is available](https://chrisschuld.com/2019/07/decorating-the-monoprice-6-zone-home-audio-multizone-controller/) illustrating the process to use this API easily on a Raspberry Pi

## Installation

npm install

## Environment Variables

`DEVICE = ` - the serial port device name (defaults to /dev/ttyUSB0)

`BAUDRATE = ` - the baud rate to use to connect to the device (defaults to 9600)

`PORT = ` - port for API to listen on (defaults to 8181)

`AMPCOUNT = <1|2|3>` - the number of amps (you can slave up to two additional amps) (defaults to 1)

`REQUERY = ` - re-query the keypads before responding to a /zones request (defaults to false)

`CORS = ` - respond to a CORS request with an `Access-Control-Allow-Origin=*` (defaults to false)

## Running the server

PORT=8181 npm start

or using more environment variables:

PORT=8181 AMPCOUNT=2 REQUERY=false BAUDRATE=115200 CORS=false npm start

## Updating the Baud Rate

You can update the baud rate of the controller to one of the following rates: 9600, 19200, 38400, 57600, 115200, 230400

By default, at power loss, the device is set to run at 9600 BAUD. You can adjust it using the `updateBaudRate.js` via npm run-script *(or directly with node)*.

```
OLDBAUDRATE=9600 NEWBAUDRATE=115200 npm run-script baudrate
```

Notes:
+ To reset the baud rate remove power from the controller for 30 seconds - it will reset to 9600 BAUD
+ Running `npm run-script baudrate` with the incorrect connection baud rate will not cause it to lock so intialization scripting could be created to reset the baudrate before the API enables.

### Environment Variables for updateBaudRate.js

`DEVICE = ` - the serial port device name (defaults to /dev/ttyUSB0)

`OLDBAUDRATE = ` - the current baud rate of the controller (the rate used to initially connect to the device)

`NEWBAUDRATE = ` - the desired baud rate

## API

### GET /zones

```js
[
{
"zone": "11",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "15",
"tr": "10",
"bs": "10",
"bl": "10",
"ch": "01",
"ls": "00"
},
{
"zone": "12",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "15",
"tr": "10",
"bs": "10",
"bl": "10",
"ch": "01",
"ls": "00"
},
{
"zone": "13",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "15",
"tr": "10",
"bs": "10",
"bl": "10",
"ch": "01",
"ls": "00"
},
{
"zone": "14",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "10",
"tr": "10",
"bs": "12",
"bl": "10",
"ch": "02",
"ls": "00"
},
{
"zone": "15",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "20",
"tr": "07",
"bs": "07",
"bl": "10",
"ch": "01",
"ls": "00"
},
{
"zone": "16",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "21",
"tr": "07",
"bs": "07",
"bl": "10",
"ch": "01",
"ls": "00"
}
]
```

### GET /zones/:zone

Returns the current status of a specific zone.

```js
{
"zone": "11",
"pa": "00",
"pr": "01",
"mu": "00",
"dt": "00",
"vo": "15",
"tr": "10",
"bs": "10",
"bl": "10",
"ch": "01",
"ls": "00"
}
```

### GET /zones/:zone/:attribute

Return the value of a specific attribute in a zone as plain text.
Valid attributes are:

pa (send zone 1 to all outputs)
power / pr
mute / mu
do not disturb / dt
volume / vo
treble / tr
bass / bs
balance / bl
channel / source / ch
keypad status / ls

$ curl 192.168.1.254:8181/zones/11/bass
10

### POST /zones/:zone/:attribute

Update a zone's attribute using the plain-text value of the body.

pa (send zone 1 to all outputs)
power / pr
mute / mu
do not disturb / dt
volume / vo
treble / tr
bass / bs
balance / bl
channel / source / ch

Here's an example where we turn the bass of zone 11 up:

```
$ curl 192.168.1.254:8181/zones/11
{"zone":"11","pa":"00","pr":"01","mu":"00","dt":"00","vo":"15","tr":"10","bs":"10","bl":"10","ch":"01","ls":"00"}
$ curl -X POST -d '12' 192.168.1.254:8181/zones/11/bass
{"zone":"11","pa":"00","pr":"01","mu":"00","dt":"00","vo":"15","tr":"10","bs":"12","bl":"10","ch":"01","ls":"00"}
```

## Device Manual

The manual for the [6 zone amp](https://www.monoprice.com/product?p_id=10761) is available (via Monoprice)[https://downloads.monoprice.com/files/manuals/10761_Manual_141028.pdf]

## Contributions

* fork
* create a feature branch
* open a Pull Request