https://github.com/stephenhillier/instr
A client/server for remote geotechnical datalogging
https://github.com/stephenhillier/instr
geotechnical-engineering go grpc
Last synced: 3 months ago
JSON representation
A client/server for remote geotechnical datalogging
- Host: GitHub
- URL: https://github.com/stephenhillier/instr
- Owner: stephenhillier
- Created: 2018-07-21T06:10:14.000Z (almost 7 years ago)
- Default Branch: master
- Last Pushed: 2018-07-21T06:10:49.000Z (almost 7 years ago)
- Last Synced: 2025-01-07T08:12:37.342Z (5 months ago)
- Topics: geotechnical-engineering, go, grpc
- Language: Go
- Homepage:
- Size: 7.37 MB
- Stars: 1
- Watchers: 2
- Forks: 0
- Open Issues: 0
-
Metadata Files:
- Readme: README.md
Awesome Lists containing this project
README
# Earthworks Instrumentation
gRPC server/client implementation for transmitting instrumentation readings to a central data store
## Server
The **instr** server receives incoming connections through gRPC from clients and stores readings in a database. Currently supports PostgreSQL (see `backend/database` folder)
## Clients
### thermThe therm client collects automated readings from a thermistor. A thermistor's resistance varies when it is heated or cooled, and the measured resistance can be converted a temperature. One application of a thermistor for civil engineering is for observing seasonal or annual trends in ground temperature.
## Instructions
### Running the Server
To run the server, a [PostgreSQL](https://www.postgresql.org/) connection is required. The application is written in Go.
Create a database user and a database. ([PostgreSQL tutorial](https://www.postgresql.org/docs/current/static/tutorial.html))
Create a table with resistance and device columns:
```sql
CREATE TABLE reading(
id SERIAL PRIMARY KEY,
resistance FLOAT NOT NULL,
device TEXT NOT NULL CHECK (char_length(device) < 100)
)
```Set the following environment variables:
* DBHOST: the database hostname (localhost if running on the same machine)
* DBPORT: the database port (postgres default is 5432)
* DBNAME: the name of your database
* DBUSER: the database user with privileges on the databaseMake sure the database is ready to accept connections and start the instrumentation server: from the `backend/server` folder, run `go run main.go`. Alternatively, build the package with `go build main.go` and execute the binary.
### Running the client
The **therm** client can be run on a Raspberry Pi with Docker. An ADS1015 analog to digital converter was used.
Build the executable in the `clients/therm` folder:
```sh
cd clients/therm
GOOS=linux GOARCH=arm go build main.go
```Build the docker image:
```
docker build -t instr .
```and run it from the Raspberry Pi (see [Docker documentation](https://docs.docker.com/) for building and pushing your own images). Use the --device flag to allow the container to access `/dev/i2c-1`:
```
docker run --device=/dev/i2c-1 instr